RééDOC
75 Boulevard Lobau
54042 NANCY cedex

Christelle Grandidier Documentaliste
03 83 52 67 64


F Nous contacter

0

Article

--";3! O
     

-A +A

The reversal of antagonists facilitates the peak rate of tension development

GABRIEL DA; BASFORD J; AN KN
ARCH PHYS MED REHABIL , 2001, vol. 82, n° 3, p. 342-346
Doc n°: 99827
Localisation : Documentation IRR

Article consultable sur : http://www.archives-pmr.org

The present study was designed to test the effects of the reversal of antagonists on the peak rate of tension development (dF/dt(max)) of the elbow extensors. DESIGN: Experimental, with matched controls. SETTING: A biomechanics research laboratory. PARTICIPANTS: Twenty-six healthy women without a history of upper extremity injury or neurologic disorder, randomly assigned to experimental (n = 13) or control (n = 13) groups. INTERVENTIONS: Two groups of healthy subjects followed identical exercise protocols, except that the control group performed maximal isometric contractions of the elbow extensors and the experimental group executed a maximal isometric elbow flexion contraction immediately before a maximal elbow extension contraction. Both groups performed 5 cycles of a 2-second contraction with 22-second rest periods between agonist muscle contractions and were evaluated at 4 test sessions spaced 2 weeks apart. MAIN OUTCOME MEASURES: All measurements were done with the shoulder and elbow at 90 degrees of flexion in the sagittal plane to ensure reproducibility. A load cell was used to measure elbow extension moment and to calculate the peak rate of tension development (dF/dt(max)). Biceps and triceps brachii surface electromyographic activity was monitored concurrently. The electromyographic measures were mean spike (peak-to-peak) amplitude and mean spike frequency of the biceps and triceps brachii activity. RESULTS: Intraclass dF/dt(max) and electromyographic reliability was good (r > or = .72) in both groups. Because biceps electromyographic measures were considerably less reliable (r < or = .53), they were not included in our analysis. While dF/dt(max) increased quadratically in both groups (p <.05), the experimental group was on average 36.1Nm. s(-1) (63%) greater across sessions 2 to 4 (p <.05). In contrast, triceps electromyographic activity did not differ significantly between groups (p >.05). The means averaged across groups exhibited a quadratic increase from session 1 to session 4: 91microV or 48% for mean spike amplitude (p <.05) and 7Hz or 16% for mean spike frequency (p <.05). CONCLUSIONS: The greater dF/dt(max) for the experimental group was not associated with increased electromyographic activity. The experimental group appeared to use the biomechanic properties of the pretensioned extensor muscle-tendon complex, rather than neurologic biasing, to accomplish its power gains.

Langue : ANGLAIS

Identifiant basis : 2001215767

Mes paniers

4

Gerer mes paniers

0