Evaluation of accuracy and precision of bone markers for the measurement of migration of hip prostheses - A comparison of conventional measurements

BIEDERMANN R; STOCKL B; KRISMER M
J BONE JOINT SURG BR , 2001, vol. 83, n° 5, p. 767-771
Doc n°: 101426
Localisation : Documentation IRR
Descripteurs : DE32 - EXPLORATION EXAMENS BILANS - HANCHE

Our aim was to determine whether tantalum m arkers improved the accuracy and/or precision of methods for the measurement of migration in total hip replacement based on conventional measurements without mathematical correction of the data, and with Ein Bild Roentgen Analyse - Femoral Component Analysis (EBRA-FCA) which allows a computerised correction. Three observers independently analysed 13 series of roentgen-stereophotogrammetric-analysis (RSA)-compatible radiographs (88). Data were obtained from conventional measurements, EBRA-FCA and the RSA method and all the results were compared with the RSA data. Radiological evaluation was also used to quantify in how many radiographs the intraosseous position of the bone markers had been simulated. The results showed that tantalum markers improve reliability whereas they do not affect accuracy for conventional measurements and for EBRA-FCA. Because of the danger of third-body wear their implantation should be avoided unless they are an integral part of the method.

Langue : ANGLAIS

Identifiant basis : 2001217377