Article

--";3! O
     

-A +A

Changes in cross-sectional area of hamstring anterior cruciate ligament grafts as a function of time following transplantation

HAMADA M; SHINO K; HORIBE S; MITSUOKA T; TORITSUKA Y; NAKAMURA N
ARTHROSCOPY , 2005, vol. 21, n° 8, p. 917-922
Doc n°: 121557
Localisation : Documentation IRR
Descripteurs : DE561 - TRAITEMENT CHIRURGICAL - GENOU

To measure the cross-sectional area (CSA) of hamstring anterior cruciate ligament (ACL) grafts in humans up to 2 years postoperatively and to estimate the appropriate graft-notch distance (the distance between ACL graft and roof or wall of the notch) at surgery. Type of Study: Case series. Methods: Fifty-nine patients, who had consented to have a magnetic resonance imaging (MRI) evaluation postoperatively, underwent endoscopic ACL reconstruction using 3 to 5-strand autogenous hamstring tendons. Intraoperatively, the CSA of the graft was measured using a custom-made area micrometer. Postoperatively, 115 axial MRIs of the grafts (48 at 3 months, 44 at 12 months, and 23 at 24 months) were obtained. They were transmitted to a personal computer and the CSAs of the grafts' midsubstance were calculated. To evaluate the accuracy of the MRI measurement, another 15 patients who consented to have MRI 2 days after surgery were selected and intraoperative graft CSA measurements and graft axial MRI were performed 2 days after surgery. Results: The CSAs of the grafts measured by MRI 2 days after surgery were well correlated with those directly measured intraoperatively (gamma = 0.905). The CSA of the grafts measured intraoperatively was 43 +/- 5 mm(2), and those estimated by MRI at 3, 12, and 24 months were 50 +/- 9 mm(2), 54 +/- 9 mm(2), and 48 +/- 12 mm(2), respectively. The increase in graft diameter at 3, 12, and 24 months was 9% +/- 8%, 13% +/- 10%, and 7% +/- 12%, respectively. Conclusions: In humans, the increase in CSA of the ACL graft was smaller compared with previous animal studies. The graft CSA increased up to 29% (13% in diameter) 12 months after surgery. When a 95% confidence interval was used, the percent increase in diameter of the reconstructed graft was estimated to be less than 32% in 95% of the cases. When the graft diameter was 7, 8, or 9 mm, a 1.1-, 1.3-, or 1.4-mm graft-notch distance, respectively, was suitable for impingement-free graft during postoperative periods with 95% of probability. Level of Evidence: Level IIII.

Langue : ANGLAIS

Tiré à part : OUI

Mes paniers

4

Gerer mes paniers

0